This system is a suitcase contained unit providing the ultimate in ease of use, portability and component storage. All pneumatic components are affixed to the steel plates which are mounted to the suitcase. The special designed suitcase’s top cover can be placed next to its bottom case as an experiment platform. This system is specifically designed to give practical and in-depth knowledge of Pneumatics, preparing students entry into industry.

Feature:
1. Portable
2. Rugged construction
3. Push-fit connectors
4. Wide range assignments
5. Genuine industrial components

Specifications:
1. Pneumatic air manifold set: 1 set
a. The air input end comes with a sliding switch.
b. 5 air outputs with 4-mm pneumatic fittings
2. Pressure gauge: 1 set
a. Range: 0 ~ 140 psi
3. Vacuum pressure gauge: 1 set
a. Range: -14.5 ~ 0 psi
4. OR valve: 5 sets
a. Two air inputs
b. One air output
c. Operating pressure: 14 ~ 125 psi
5. AND valve: 2 sets
a. Two air inputs
b. One air output
c. Operating pressure: 14 ~ 125 psi
6. Vacuum generator: 1 set
a. Operating pressure: 14 ~ 85 psi
b. Vacuum level: 13 psi
c. Air consumption: 44 L/min
7. Single acting 3W/2P NC spring return valve: 1 set
a. Air in: P
b. Air out: A
c. Control : Z
d. Operating pressure: 20 ~ 115 psi
8. Single acting 3W/2P NO spring return valve: 1 set
a. Air in: P
b. Air out: A
c. Control : Z
d. Operating pressure: 20 ~ 115 psi
9. Double acting 3W/2P valve: 1 set
a. Air in: P
b. Air out: A
c. Control : Y, Z
d. Operating pressure: 20 ~ 115 psi
10. Single acting 5W/2P spring return valve: 1 set
a. Air in: P
b. Air out: A, B
c. Control: Z
d. Operating pressure: 20 ~ 115 psi
11. Double acting 5W/2P valve: 3 setsptl 12011 w3
a. Air in: P
b. Air out: A, B
c. Control: Y, Z
d. Operating pressure: 20 ~ 115 psi
12. Double acting 5W/3P center closed, spring return valve: 1 set
a. Air in: P
b. Air out: A, B
c. Control: Y, Z
d. Operating pressure: 20 ~ 115 psi
13. Pressure regulator: 1 set
a. Operating range: 7 ~ 125 psi
14. 3W/2P push-button operated valve: 2 sets
a. Air in: P
b. Air out: A
c. Push buttons: Green, Red
15. 5W/2P emergency switch: 1 set
a. Air in: P
b. Air out: A
c. Push-luck, turn-reset switch
16. Pneumatic time delay valve: 1 set
a. Air in: P
b. Air out: A
c. Control: Z
d. Timer
e. Operating pressure: 5 ~ 140 psi
17. Pneumatic counter: 1 set
a. Air in: P
b. Air out: A
c. Range: 0 ~99999
d. Operating pressure: 28 ~ 125 psi
18. Sequential valve: 1 set
a. Air in: P
b. Air out: A
c. Control: Z
d. Operating pressure: 5 ~ 100 psi
19. Vacuum sequence valve: 1 set
a. Air in: P
b. Air out: A
20. Air buffer set: 1 set
21. Single acting cylinder: 1 set
a. Air flow adjustor
b. Stroke: 4 inches (100 mm)
22. Double acting cylinder: 2 sets
a. Air flow adjustor
b. Strokes: 4 inches (100 mm) and 5 inches (125 mm)
23. 3W/2P 2-way, roller operated valve: 4 sets
a. Air in: P
b. Air out: A
c. Two-way roller operated, spring return
d. Operating pressure: 14 ~ 125 psi
24. 3W/2P one-way , roller operated valve: 1 set
a. Air in: P
b. Air out: A
c. One-way roller operated, spring return
d. Operating pressure: 14 ~ 125 psi

ptl 12011 w2Experiments:

1.Single Acting Cylinder Control

2.Double Acting Cylinder Control

3.OR Valve Control

4.AND Valve Control

5.Direction Valve Control

6.Sequential Valve Control

7.Time-delay valve Control

8.Pneumatic Counter Control

9.Roller operated Valve Control

10.Vacuum Generator Control

11.Manual Safety Loop Control

12.Single Acting Cylinder Loop Control

13.Double Acting Cylinder Loop Control

14.Cylinder Control with Pressure Return

15.Time-delay Valve in Cylinder Control

16.Dual-button, Cylinder Control with Auto Return

17.Double Acting Cylinder, Multiple Loops Control

18.Emergency Switch in Loop Control

19.Dual-roller, Sequential Control

20.Manual and Auto Loop Control